Predicate Devices: Synthes Stainless Steel Modular Hand System Synthes Modular Foot System Synthes Modular Foot System- 2.7 mm Module Device Description: The Synthes (USA) Modular Mini Fragment LCP System includes 2.0, 2.4, and 2.7 mm size implants. The system incorporates a

6 DePuy Synthes Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical Technique Postoperative, AP view Postoperative, lateral view, 20° inclined Postoperative, AP view Postoperative, lateral view Clinical Cases Case 1 24-year-old male with AO 23C2.1 fracture, fall from scaffold Preoperative, AP view Preoperative, lateral viewThe DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who has The DePuy Synthes VA-LCP Clavicle Plate 2.7 System of implantable devices consists of lateral, shaft and medial plates. Plates are available in various sizes in both sterile and non-sterile package configurations. The system also consists of non-implantable templates that correspond to the above listed implants.

Mod hand synthes. Things To Know About Mod hand synthes.

2 DePuy Synthes 2.4 ®mm Variable Angle LCP Distal Radius System Surgical Technique. 2.4 MM VARIABLE ANGLE LCP DISTAL RADIUS SYSTEM. Plate features. Three head sizes accommodate . patient anatomy. • Narrow – 6-hole head (19.5 mm) • Standard – 6-hole head (22 mm) – 7-hole head (25.5 mm) • Anatomically contoured volar distalSynthes GmbH Eimattstrasse 3 CH-4436 Oberdorf www.synthes.com 0123 Ö036.000.206öAAkä Setlist Modular Trays TEN System 01.009.011 Modular TEN Instrument Tray, size 1/1, with Contents 68.009.001 Modular Tray, size 1/1, for TEN Instruments, without Contents 359.217 Cutter for TEN 1 359.213 Awl for TEN 1 359.219 … benefits of using the DePuy Synthes Variable Angle (VA) Locking Hand System for fracture fixation of the hand. The referenced data for this value brief were obtained through a search of MEDLINE on the current practice patterns for the management of hand fractures with a focus on biomechanical and 4 Surgical Technique • LCP Compact Foot/Compact Hand 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures. The implant plates of the APTUS Hand/Wrist Arthrodesis System 2.0/2.3, 2.5 are available in the following designs: Description Example Main Feature Plate Thickness System 2.0/2.3 TriLock STT Fusion Plate A-4660.15 Locking 1.4 mm 2.0/2.3 2.0/2.3 TriLock Four Corner Fusion Plates A-4660.10 Locking 1.4 mm 2.0/2.3 Small A-4660.11 Locking 1.4 mm 2.0/2.3

Implants (cont’d) Instruments 3 3.5 mm One-Third Tubular Plate Holes 241.344 241.355 241.366 241.388 Washer 219.98 7.0 mm Buttress Pin 201.980 1.8 mm, 30 mm Kirschner WiresPart 1 of 5: Watch this video to learn more as Dr. Fischer and Dr. Richard demonstrate surgical techniques using the DePuy Synthes Variable Angle Locking Hand System in this five-chapter series. In this video, they provide an overview of the system and focus on the comprehensive instruments available in the set. This content is intended for Health Care Professionals in the United States. To ...Are you looking for a way to take your gaming experience to the next level? Mod menus are a great way to do just that. Mod menus are special programs that allow you to customize yo...

The following is a step-by-step guide to internal fixation of a middle phalangeal fracture using the well-established lag screw compression technique. This procedure demonstrates the use of 1.3 mm screws from the Synthes ® Compact Hand Set. Manish Gupta. Consultant Hand Surgeon, Queen Elizabeth Hospital ,Birmingham ,UK.Features & Benefits. Power Module designed for increased lifetime and cost effectiveness 1. Intelligent design allowing instant battery capacity and function check. Comprehensive range of drilling, reaming and sawing attachments for more flexibility in the OR 2.

08/16. Instructions for Use. Plate and Screw Implants Associated device systems with these instructions for use: 2.4 mm Cannulated Screw 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System 2.4/2.7 mm Locking Tarsal Plates Angled Blade Plates for Adults Angular Stable X-Plate and 2-Hole Plate Cannulated Angled Blade Plate 3.5 ...The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.The Stryker Hand Plating module houses the VariAx Hand Locking and Profyle Hand Systems which offer the benefits of a comprehensive range of variable angled locking …Synthes 421.306 Plate, 1.3mm, Titanium, Straight, 6 Hole, Hand Surgery. $100.00. SKU: 421.306 Condition: New Availability: out of stock, search our store for more titanium Synthes implants Current Stock: Out of stock Out of …Please read these instructions for use, the Synthes brochure “Important Informa-tion” carefully before use. Ensure that you are familiar with the appropriate surgical technique. The DePuy Synthes COMPACT 2.0 and COMPACT 2.4 Trauma Plates and Screws System Mandible consist of divers systems offering a variety of plates that come in

The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.

Arthrex Ar-6549 Surgical Reusable Orthopedic Obturator Instrument. Find many great new & used options and get the best deals for Synthes Titanium Modular Mod Hand System Orthopedic Trauma at the best online prices at eBay! Free shipping for many products! Modding your Gorilla Tag can be a great way to customize your gaming experience and make it more enjoyable. But if you don’t have access to a computer, you may think that modding i... DePuy Synthes is a business unit of Johnson & Johnson (New Zealand) Ltd. 507 Mount Wellington Highway, Mount Wellington, Auckland, 1060, New Zealand. Discover the Variable Angle Locking Hand System: provides an extensive range of basic and specialty plates for fracture repair and deformity correction. Hand and Wrist. Hand Products. BME Speed Implant; Continuous Compression Implants; Variable Angle Locking Hand System; Variable Angle Locking Intercarpal Fusion System; Wrist Products. Variable Angle LCP™ Distal Radius Sterile Kit; Variable Angle LCP™ Two-Column Volar Distal Radius Plate; 2.4 mm Variable Angle LCP Volar Extra-Articular ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ... PRODUCT CODES. DESCRIPTION. The Orthopaedic Foot Instruments system was created to perform a variety of orthopaedic reconstructive procedures by combining three modular sets. These sets offer compression, distraction, joint preparation, and bone harvesting capabilities for a variety of foot and ankle procedures. Product Specifications. ... synthes mini fragment set inventory sheet. synthes mini fragment surgical technique synthes titanium mini frag lcp mini frag synthes mod mini inventory synthes ...

Mod Podge consists mostly of water and polyvinyl acetate, a common ingredient in most white glues. The water-resistant properties of polyvinyl acetate make Mod Podge a useful top c...Mod Podge consists mostly of water and polyvinyl acetate, a common ingredient in most white glues. The water-resistant properties of polyvinyl acetate make Mod Podge a useful top c...synthes.vo.llnwd.netClinical Resources. Surgical Technique Guide. Instructions for Use. The VA-LCP Condylar Plate 4.5/5.0 is part of the VA-LCP Periarticular Plating System which merges Variable Angle Locking Screw Technology with conventional plating techniques.LC-DCP SYNTHES Small Fragment Set Titanium LC DCP. Synthes. $2,950.00. SYNTHES MAXILLOFACIAL CRANIOFACIAL MODULAR FIXATION SYSTEM 1.3mm CRANIAL MODULE. Synthes. Sold out. SYNTHES 4.0 MM Cannulated Screw Set Orthopedic Surgery 4mm. Synthes. $1,490.00.

The OsteoMed Hand Plating System (HPS) features low-profile implants and instrumentation designed specifically for treating hand trauma. The HPS Plates are available in four size modules: 1.2, 1.6, 2.0, and 2.4 mm, and accept up to four screw types: VA locking, nonlocking, lag, and cannulated. Also featured are hand fusion plates in two ... Make these fast steps to change the PDF Synthes mini fragment set inventory sheet online for free: Sign up and log in to your account. Log in to the editor using your credentials or click Create free account to evaluate the tool’s capabilities. Add the Synthes mini fragment set inventory sheet for editing.

The AOTK approved Variable Angle Locking Hand System is the next generation of small implants for the hand consisting of plates that are anatomic, both fracture and procedure-specific and available in stainless steel and titanium. The system was designed to address clinical challenges faced in the current fixation of fractures and osteotomies and …Gorilla Tags are a popular way to customize your gaming experience. With the right modding tools, you can make your Gorilla Tag look and feel exactly the way you want it to. But wh...Product Overview. The Acumed Hand Fracture System is designed to surgically treat various metacarpal and phalangeal fractures, fusions, and osteotomies and includes five solutions in one tray. Versatile screws, customizable plates, and dedicated instrumentation offer a comprehensive system to streamline the surgical experience. The following is a step-by-step guide to internal fixation of a middle phalangeal fracture using the well-established lag screw compression technique. This procedure demonstrates the use of 1.3 mm screws from the Synthes ® Compact Hand Set. Manish Gupta. Consultant Hand Surgeon, Queen Elizabeth Hospital ,Birmingham ,UK. The modular CMFD system offers a low-profile stable distraction construct without unintentional reversal combined with intraoperative flexibility and ease-of-use during application and removal. 1-3. Anti-reversal detent clip is contained within distractor body for a consistent, smooth profile that helps reduce impact to soft tissue. 1,4.Our e-learning platform contains high resolution images and a certified CME of the Internal fixation of 5th metacarpal neck fracture (Synthes LCP plate) surgical procedure. Metacarpal neck fractures are very common in the hand. The “Boxer’s” fracture in the 5 th metacarpal neck is one of the commonest injuries that present to a Hand ...Slightly tighten the cable by hand until it embraces the bone. Insert the cable into the Cable Tensioner. Advance the Cable Tensioner along the cable until the attachment bit rests against the cable crimp. Hold the cable in place by pushing the lever of the cable lock in the ”LOCK” direction . Confirm the placement of the crimp on the bone.

About This System. This range of implants with locking technology are available in different plates: 1.3 mm Locking Plates. 1.5 mm Variable Angle Locking Plates. 2.0 mm Variable Angle Locking Plates. Get in Touch with a Sales Consultant.

The Variable Angle LCP™ Forefoot-Midfoot System offers a wide range of low-profile plates with variable angle (VA) screw placement and compression system designed within the plates to help minimize additional soft tissue dissection. Available in stainless steel and titanium. Product Specifications.

Part 1 of 5: Watch this video to learn more as Dr. Fischer and Dr. Richard demonstrate surgical techniques using the DePuy Synthes Variable Angle Locking Hand System in this five-chapter series. In this video, they provide an overview of the system and focus on the comprehensive instruments available in the set. This content is intended for Health Care …About This Product. The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.Select the plate according to the fracture pattern and the - This technique guide describes the application of the LCP Compact Hand 1.5 system using a Locking Condylar - Familiarity with the use of LCP plates or instruction from an experienced surgeon is recommended (see LCP Locking Compression Plate technique guide...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...Synthes 3.2mm Percutaneous Drill Bit QC/ 300mm/ Calibrated 324.212 $ 125.00 Add to cart; Synthes 6.5mm Tap Calibrated To 150mm / 197mm O.L 311.66 $ 150.00 Add to cart; Medtronic Surgical Midas Rex Attachment 9BA40D IN DATE! $ 75.00 Add to cart; Depuy Surgical Hand Fracture Instrument Set W/ Case Synthes Surgical Distal Radius Fixator …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ...Find out more on the 3.5mm LCP® Superior Anterior Clavicle Plate and Superior Clavicle Plate developed by DePuy Synthes with locking screw technology.DePuy Synthes Trauma Variable angle locking calcaneal Plating System to treat a wide variety of calcaneal fracture types. this plating system consists of the 2.7 mm Variable angle locking calcaneal Plate for oriF procedures as well as a 2.7 mm Variable angle locking anterolateral calcaneal Plate for use miPo surgical approach inThe Stryker Hand Plating module houses the VariAx Hand Locking and Profyle Hand Systems which offer the benefits of a comprehensive range of variable angled locking and non-locking plating options to treat fractures of bones of the hand and wrist. Plates utilize SmartLock Technology which permits polyaxial screw placement. You can angle locking …The following is a step-by-step guide to internal fixation of a middle phalangeal fracture using the well-established lag screw compression technique. This procedure demonstrates the use of 1.3 mm screws from the Synthes ® Compact Hand Set. Manish Gupta. Consultant Hand Surgeon, Queen Elizabeth Hospital ,Birmingham ,UK.Consult Depuy Synthes's entire LCP Compact Hand catalogue on MedicalExpo. Page: 1/28 components necessary for the DePuy Synthes Variable Angle Locking Hand System. DePuy Synthes Companies are dedicated to improving patient care. System Snapshot x Extensive system of anatomically precontoured plates x First to the market with 1.3 mm locking screws for hand plating1 x Forceps that aid in fracture reduction and lag screw application

Mod menus are a great way to customize your gaming experience and add new features to your favorite games. But with so many mod menus available, it can be hard to know which one is...The Arthrex Mini Comprehensive Fixation System (Mini CFS) is a comprehensive solution for mini fragment fixation and fusion needs. Multiple modules within the system offer 1.0 mm screws, 1.4 mm plates/screws, 1.6 mm plates/screws, 2.0 mm plates/screws, and 2.4 mm plates/screws along with associated instrumentation. Each …The Modular Mini Fragment LCP™ System is an instrument and implant module set intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. Product Specifications. How to Use This Product.Instagram:https://instagram. northwell office150 grain 308 ballistics charthidive xbox appare jim breheny and kathleen lamattina still married The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who has honeywell mn12ces replacement partsgh spoilers sonny Hand and Wrist. Hand Products. BME Speed Implant; Continuous Compression Implants; Variable Angle Locking Hand System; Variable Angle Locking Intercarpal Fusion System; Wrist Products. Variable Angle LCP™ Distal Radius Sterile Kit; Variable Angle LCP™ Two-Column Volar Distal Radius Plate; 2.4 mm Variable Angle LCP Volar Extra-Articular ...Here you can find thousands of user created content for games - mods, like custom vehicles, maps, also tutorials, cheats and news about the latest games! Choose the game you want to explore below, join our large and growing gaming social network, choose from our large collection of content and download modifications completely for free. Our user … how to look up a gun's serial number 0X.211.201 – X-Plates 2.4/2.7, VA locking 0X.211.204 (Extra-Small, Small, Medium, Large) For full ordering information and product details please refer to technique guide “Variable Angle LCP Forefoot/Midfoot System 2.4/2.7” 036.001.232. The general fusion plates consist of variable angle cortex screws, and a compression feature to tive ...The Variable Angle LCP™ Forefoot-Midfoot System offers a wide range of low-profile plates with variable angle (VA) screw placement and compression system designed within the plates to help minimize additional soft tissue dissection. Available in stainless steel and titanium. Product Specifications.6 DePuy Synthes Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical Technique Postoperative, AP view Postoperative, lateral view, 20° inclined Postoperative, AP view Postoperative, lateral view Clinical Cases Case 1 24-year-old male with AO 23C2.1 fracture, fall from scaffold Preoperative, AP view Preoperative, lateral view